The active distribution network (ADN) represents the future development of distribution networks, whether the islanding phenomenon occurs or not determines the control strategy adopted by the ADN. The best wavelet packet has a better time-frequency characteristic than traditional wavelet analysis in the different signal processing, because it can extract better and more information from the signal effectively. Based on wavelet packet energy and the neural network, the islanding phenomenon of the ADN can be detected. Firstly, the wavelet packet is used to decompose current and voltage signals of the public coupling point between the distributed photovoltaic (PV) system and power grid, and calculate the energy value of each decomposed frequency band. Secondly, the network is trained using the constructed energy characteristic matrix as a neural network learning sample. At last, in order to achieve the function of identification for islanding detection, lots of samples are trained in the neural network. Based on the actual circumstance of PV operation in the ADN, the MATLAB/SIMULINK simulation model of the ADN is established. After the simulation, there are good output results, which show that the method has the characteristics of high identification accuracy and strong generalization ability.
Go to article

Abstract

When the machine is at high speed, serious problems occur, such as high frequency loss, difficult thermal management, and the rotor structural strength insufficiency. In this paper, the performances of two high-speed permanent magnet generators (HSP- MGs) with different rotational speeds and the same torque are compared and analyzed. The two-dimensional finite element model (FEM) of the 117 kW, 60 000 rpm HSPMG is established. By comparing a calculation result and test data, the accuracy of the model is verified. On this basis, the 40 kW, 20 000 rpm HSPMG is designed and the FEM is established. The relationship between the voltage regulation sensitivity and power factor of the two HSPMGs is determined. The influence mechanism of the voltage regulation sensitivity is further revealed. In addition, the air-gap flux density is decomposed by the Fourier transform principle, and the influence degree of different harmonic orders on the HSPMG performance is determined. The method to reduce the harmonic content is further proposed. Finally, the method to improve the HSPMG overload capacity is obtained by studying the maximum power. The research showed that the HSPMG at low speed (20 000 rpm) has high sensitivity of the voltage regulation, while the HSPMG at high speed (60 000 rpm) is superior to the HSPMG at low speed in reducing the harmonic content and increasing the overload capacity.
Go to article

Abstract

The chaotic phenomena of coronary artery systems are hazardous to health and may induce illness development. From the perspective of engineering, the potential harm can be eliminated by synchronizing chaotic coronary artery systems with a normal one. This paper investigates the chaos synchronization problem in light of the methodology of sliding mode control (SMC). Firstly, the nonlinear dynamics of coronary artery systems are presented. Since the coronary artery systems suffer from uncertainties, the technique of derivative-integral terminal SMC is employed to achieve the chaos synchronization task. The stability of such a control system is proven in the sense of Lyapunov. To verify the feasibility and effectiveness of the proposed method, some simulation results are illustrated in comparison with a benchmark.
Go to article

Abstract

With the continuous increase of output power ratings, multi-phase (multichannel) interleaved power factor corrector (IPFC) is gradually employed in domestic and commercial inverter air-conditioners. IPFC can solve several main problems, such as power rating increase, power device selection, input current ripple reduction as well as inductor on-board mounting. But for a multi-phase IPFC, the key problem is that it should show rapid dynamic responds and good current sharing capability, so in this paper the aim is to improve the dynamic performance and current sharing capability by means of passivity control theory. Considering the power circuit topology of a four-phase IPFC, an EL (Euler-Lagrange) mathematical model is established when the IPFC operates in continuous conduction mode (CCM). Then the passivity of the four-phase IPFC is proved, and the passivity-based controller using the state variables feedback and damping injection method is designed. The proposed control scheme, which is easy to control and needs no proportion integral controller, has strong robustness on disturbance from singlephase AC input voltage, the load as well as the parameters of the employed devices. Even in wide-range load condition, the mains current has a fast dynamic response and the average output voltage almost keep unchanged. As a result, the main functions of the four-phase IPFC are implemented including nearly unitary power factor and constant DC output voltage. Meanwhile, the four-phase IPFC acquires an excellent current sparing effect after using passivity-based controller. The above analysis has been proved with simulated results by means of MATLAB/SIMULINK and experimental results, showing that the passivity-based IPFC controller has superior performances and feasibility.
Go to article

Abstract

A novel phase shift full bridge (PSFB) converter with voltage-doubler and decoupling integrated magnetics in photovoltaic (PV) systems is proposed. Considering the demand that the output voltage is higher than the input voltage in PV systems, the voltage-doubler is added to achieve higher voltage gain compared with the traditional PSFB. In order to avoid current oscillation caused by the voltage-doubler and obtain the wide zero voltage switching (ZVS) ranges, an external inductor is imposed on the circuit. Especially, to obtain much higher power density, the external inductor and transformer are integrated into one magnetic core. The operation and voltage gain of proposed converter are analyzed. Also, in order to reveal the effects the integrated magnetics gives to the converter, the decoupling condition and the expression of leakage inductor of integrated magnetics are obtained in detail. Finally a 100 W prototype converter is made and the experimental results are given to verify the analysis.
Go to article

Abstract

In this paper, crushability of foundry sand particles was studied. Three kinds of in-service silica sands in foundry enterprises selected as the study object, and foundry sand particles were subjected to mechanical load and thermal load during service were analyzed. A set of methods for simulating mechanical load and thermal load by milling and thermal-cold cycling were designed and researched, which were used to characterize the crushability for silica sand particles, the microstructure was observed by SEM. According to the user’s experience in actual application, the crushability of Sand C was the best and then Sand B, the last Sand A. The results indicated that mechanical load, thermal load and thermal-mechanical load can all be used to characterize the crushability of foundry sand particles. Microscopic appearances can qualitatively characterize the crushability of foundry sand particles to a certain extent, combining with the additions and cracks which are observed on the surface.